DCC CONTROL

Items 251-300 of 341

per page
Set Descending Direction
  1. SPECIAL ORDER ONLY

    NCE CS-02 Command Station

    The CS 02 is the NCE Power Pro Command Station and is the most user friendly DCC system on the market. Plug in EPROMs allow you to update the system and no need to return the unit to the factory.
    This is and ideal path for those wishing to move from another DCC system and seeking the NCE advantage. When migrating please contact us as most boosters are compatible with the NCE CS 02 Command station.
    CS 02 Specifications:
    * Cabs: 60 maximum
    * Number of simultaneous trains: 250
    * Number of consists: 127 
    * Range of locomotive addresses: 0-9999
    * Range of consist addresses: 1-127
    * Range of accessory addresses: 1-2044
    * RS232 computer interface included
    DCC Command Station
    A$0.00
    Out of stock
  2. NCE Pro Cab

    The Pro Cab throttle provides the most user-friendly access to all system features. Uncomplicated menus on the easy to read, the backlit LCD display will guide you through the most advanced operations with a minimum of fuss.

    The Pro Cab-R throttle has the same specification as the Pro Cab except that a radio board and battery holder has been added for operation as a radio throttle while retaining the plug capability of the Pro Cab.

    FUNCTION CONTROL FOR THE LOCOMOTIVE LIGHTS F9 to F12

    NUMBER KEYS

    The keys 0 through 9.

    When operating a loco if a number key is pressed it toggles the corresponding function on the loco. Use to access FUNCTIONS 1 to 9.

    To access the function F9 you simply press 9

     SHIFT BUTTON

    When pressed and held while pressing another key on the cab the alternate value of that key can be used.

    To access the function F10 you simply press SHIFT and PROG/ESC at the same time to activate FUNCTION 10.

    To access the function F11 you simply press SHIFT and EXPN at the same time to activate FUNCTION 11.

    To access the function F12 you simply press SHIFT and 28/128 at the same time to activate FUNCTION 12.

    Repeat the procedure to turn the function off.

    How to operate the DCC Solutions 28 functions on your locomotive.

     EXTENDED FUNCTION CONTROL F10 to F28

     OPTION BUTTON

    The OPTIONS button marked * (see picture) can be reprogrammed for use to access FUNCTIONS 10 to 28. Follow these simple steps.

    1. Turn on your system and unplug the cable from your cab (Throttle)

    2. Press and hold down the SELECT LOCO while plugging the cable back into your cab. The cab will now enter the initial setup program. At any time you may press PROG/ESC to exit.

    3. Press enter FOUR (4) or possible FIVE (5) times depending on your cabs firmware until your screen reads PROG OPTION KEY...KEY VALUE = 94.

    4. Enter a new value of 122 and press ENTER

    5. Press PROG/ESC to exit.

    Once reprogrammed pressing OPTION once will display F10 – F19 and pressing it twice will display F20 – F28. Pressing a number key will toggle that number plus 10. Example: Press OPTION once then 5 will activate F15. Repeat the same procedure to turn F15 off.

     

    Click ADD to view options & prices.
    A$0.00
  3. NCE PowerCab

    A DCC system in the palm of your hand! Can handle 2 or 3  HO sized trains, or 4 N scale trains.
    Power Cab provides all of the capability and ease of use that you’ve heard about in our Power Pro system, at an entry level price. Hook two wires to your track and plug in the cab and you’re running trains under DCC using the most advanced entry level system on the market.
    The Power Cab can be expanded into either a full NCE Pro with all the features you have come to expect from NCE or increase its power to run a larger layout with the Smart Booster. The Smart Booster increases the PowerCab to a full 5 amps suitable for all small to medium layout's

    All warranty and service conducted in Australia by approved NCE technician

    PowerCab Specifications:

    * Cabs: 2 maximum plus USB &/or Mini Panel
    * Number of simultaneous trains: 12
    * Number of consists: 112 - 127 
    * Range of locomotive addresses: 0-9999
    * Range of consist addresses: 1-127
    * Range of accessory addresses: 1-2044
    * Continuous Output Current: 1.4 amps peak
    * Power supply: Australian approved included 
    * Output voltage: 13.4 Volts
    * Computer interface: USB optional

    Power Supply

    The NCE PowerCab MUST be operated with a factory approved power supply that is supplied with the system. Failure to use this transformer will destroy your PowerCab resulting in expensive repair charges.
    DCC system - Starter Set
    A$410.00
  4. NCE SB5 Smart Booster

    The SB5 Smart Booster expands the features of the Power Cab DCC System
    * Supplied with 5 amp DC power supply
    * Use up to 6 cabs with the SB5
    * Converts to plain booster to expand to a PowerPro
    * Use the PowerCab as a walk around throttle
    * Peak Output Current: 5.0 Amps - 3.5 Amps continuous
    * Power supply: DC supplied with AU plug
    * Short circuit handling: Auto-shutdown [500mS] 
    * Output voltage: Factory set 

     SB5 specification:

    * Maximum number of cabs: 6 [range 2 to 7] 
       plus USB/AIU/Mini panel range 8 - 10 
    * Maximum number of simultaneous trains: 18 
    * Functions controlled: 29
    * Locomotive address range 1 -127 [shot] 0-9999 [long] 
    * Accessory Range: 1 - 2044
    * Signal Address Range: 1 - 2044
    * Maximum number of adv. consists: 16 [range 112 - 127] 
    * Maximum number of old-style consists: 6 per cab [36 total]

    IMPORTANT 

    The SB5 can only be left on a short or overload for a maximum of 1 - 2 minutes. To ensure that the system is protected for a longer period all Australian supplied systems will have an EB1 circuit breaker supplied set to 2.5 amps.

    The maximum amps permitted is 3.5 per EB1

    Failure to install and test EB1 as per attached instruction voids warranty.

    5 amp DCC system /w circuit breaker
    A$540.00
  5. NCE Cab06 and Cab06R

    The Cab06e uses an encoder knob for speed control. The Cab06 can be set to YARD mode. Yard mode makes the speed knob act as a "centre off" speed control. Turn the knob to the right and the loco will increase speed in the forward direction. Turn it to the left and speed will decrease until it gets to zero then it will start to increase speed in the reverse direction the farther you turn it to the left. Selection and control of individual or entire routes through turnouts (via the MACRO key), and our unique OPTION button that can be programmed to act as any button you wish, even those found on a much larger cab.

    • Additional features include a 4-digit LED display, 29 functions, accessories with 6 recalls, including PowerCab

    • The Cab06eR has the same specification as the Cab06, except that a radio board and battery holder have been added for operation as a radio throttle while retaining the plug capability of the CAB06. 
    • For those who do not wish to use an encoder, NCE offer the CAB06P and CAB06PR. All the great features of the CAB06e but with a potentiometer.

    • The MRRC recommends the Cab06P for radio operation as it offers a physical stop to mark stop.
    Click ADD to view options & prices.
    A$0.00
  6. NCE DCC Twin

    3 Amp DCC starter set, includes 3 Amp (42 Watt) power supply.  Control two decoder equipped trains simultaneously right out of the box.  The expansion port allows you to add up to 6 walk around tethered or wireless throttles.  All throttles made by NCE are compatible.  Up to three additional cab bus accessories such as USB, AIU or mini-panels are also supported. 

    DCC Twin specification: 

    * Maximum number of simultaneous trains: 18 [with add on throttles]
    * Locomotive address range 1 -127 [short] 0-9999 [long] 
    * Functions controlled: 9
    * Maximium number of cabs 8 including the two for the DCC Twin 
    plus up to 3 USB, AIU or Mini Panel
    DCC Starter System
    A$335.00
  7. Ultra-Miniature Simulator Circuit Board - DCC & Stationary Use; Input 6-18V DC

    Steam Locomotive Class Light

    Lighting Effects Circuit for Any Scale

    Smaller than any decoder at just .31" x .31" x .118" and utilizing the industry's smallest microcontroller and associated voltage control circuitry, the total module consumes less than 500 µa (<1/2 ma). Typical peak operating current for these modules with LED(s) attached and running through full brightness curves range from 18-38 ma. This makes them ideally suited for operation when powered directly by a function output of any of today's HO, N or Z-scale DCC decoders. Designed specifically to provide truly realistic lighting effects for 20ma LEDs, these modules include input protection against reverse polarity. Input voltage range 6-18 VDC. On-board current limiting resistor. Extra input wires included. LEDs sold separately.

    tr
    A$25.00
  8. LAIS

    2-Pin Micro Connector, Black & Blue wires - 150mm long.

    This quick plug connecter is ideal for hardwire situations where you may have to remove or disconnect certain components from time to time. This quick plug connector is also ideal for “Break Away” applications where connections need to be broken easily for safety or convenience. Each side of the connector has a blue and a black (for polarity matching), 32 gauge, very flexible decoder wire soldered to it and insulated with heat shrink tubing.

     

    860028
    A$8.00
  9. LAIS

    NEM 652 Fixed wired harness

    With the use of these 8-pin 652 sockets harnesses, enables you to fit dcc decoder to non dcc locomotive
    allows non dcc trains to be converted to dcc without having to wire dcc decoder straight into the train, the socket is fitted with a adhesive pad to attach to the train in case a fault on the dcc decoder arises its easy to remove dcc decoder and replace within minutes

    tr
    A$8.00

Items 251-300 of 341

per page
Set Descending Direction
© 2019 MRRC . All Rights Reserved.